Vortex Flow Sensors


Alternate vortices rotating in opposite directions are generated behind a bluff body immersed in a flow. The vortices detach from the edges of the bluff body and form a Kármán vortex street in the fluid stream. The distance between the single vortices is constant. The frequency of the vortices flowing past a sensor depends on the flow rate and is proportional to the flow. The sensor detects these vortices which are then converted to an electrical frequency signal.     

Some of the advantages of this measuring principle:

  • Almost free pipe cross section > low pressure drop  
  • Wide range of applications in terms of pressure, temperature and density
  • Independent of the conductivity of the medium
  • High long-term stability / no zero drift

Our Vortex VVX series flow sensors offer the following compelling features:

  • Solid state flow sensor with no moving parts for liquids → no mechanical wear
  • Rugged glass fibre reinforced plastic ensures highest strength and performance
  • Completely encapsulated piezoceramic sensor to detect the vortices → thus no direct contact with the medium
  • Wide measuring span (1:21)
  • Temperature sensor integrated
  • Output signals: analogue voltage signals and / or pulse signal is available for the flow, and a resistance or analogue signal is available for the temperature.
  • High interference resistance
  • Thread connection or QuickFasten

Vortex flow sensor Type VVX15

SIKA VVX15 flow sensors are used for measuring water flow at low and medium measurement ranges.
One such application area is heating systems.

Nominal diameter DN 15
Flow range 2...40 l/min
Process connection G¾-ISO 228 male, incl. O-rings
Accuracy ±2 % of full scale*
Pressure rating PN 10

Temperature ranges

Medium
Ambient

 

5...90 °C -20...90 °C**
5...70 °C → Repeatability ±0,5 %, -20...5 °C → Repeatability ±1 %

Frequency output Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 20 mA

Analogue output

Output signal flow

 

0.5...3.5 V
0...10 V or 4...20 mA

Power supply 8...30 V DC or 5 V DC (±5 %) or 12...24 VDC****
Electrical connection 5-pin plug connector M12 x 1
Degree of protection EN 60529 IP65***

* Test conditions: See data sheet
** Temperature cycle test: See data sheet
*** With attached cable socket only
**** Only available for output signal flow 4...20 mA and 0...10 V

Options

Recognized component ETL according to UL & CSA standards available on request

Vortex flow sensor Type VVX20

SIKA VVX20 flow sensors are used for measuring water flow at low and medium measurement ranges.
One such application area is heating systems.

Nominal diameter DN 20
Flow range 5...80 l/min
Process connection
 
QuickFasten or
G1-ISO 228 male, incl. O-rings
Accuracy ±2 % of range*
Pressure rating PN 10

Temperature ranges

Medium
Ambient

 

5...90 °C, -20...90 °C**
5...70 °C → Repeatability ±0,5 %, -20...5 °C → Repeatability ±1 %

Frequency output Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 20 mA

Analogue output

Output signal flow
 


0.5...3.5 V
0...10 V or 4...20 mA
Power supply 8...30 V DC or 5 V DC (±5 %) or 12...24 VDC****
Electrical connection 5-pin plug connector M12 x 1
Degree of protection EN 60529

IP65***

* Test conditions: See data sheet
** Temperature cycle test: See data sheet
*** With attached cable socket only
**** Only available for output signal flow 4...20 mA and 0...10 V
 

Options

Recognized component ETL according to UL & CSA standards available on request

Vortex flow sensor Type VVX25

SIKA VVX20 flow sensors are used for measuring water flow at low and medium measurement ranges.
One such application area is heating systems.

Nominal diameter DN 25
Flow range 7...150 l/min
Process connection G 1¼-ISO 228 male, incl. O-rings
Accuracy ±2 % of full scale*
Pressure rating PN 10

Temperature ranges

Medium
Ambient

 

5...90 °C -20...90 °C**
5...70 °C → Repeatability ±0,5 %, -20...5 °C → Repeatability ±1 %

Frequency output Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 20 mA

Analogue output

Output signal flow
 


0.5...3.5 V
0...10 V or 4...20 mA

Power supply 8...30 V DC or 5 V DC (±5 %) or 12...24 VDC****
Electrical connection 5-pin plug connector M12 x 1
Degree of protection EN 60529

IP65***

* Test conditions: See data sheet
** Temperature cycle test: See data sheet
*** With attached cable socket only
**** Only available for output signal flow 4...20 mA and 0...10 V

Options

  • Recognized component ETL according to UL & CSA standards available on request

 

** NEW ** Vortex flow sensor Type VVX32

SIKA VVX32 flow sensors are used for measuring water flow at medium and high measurement ranges.
One such application area is large heat pumps.

Nominal diameter DN 32
Measuring range (flow) 12...250 l/min
Accuracy (flow) ±2 % of range*, deviations with high viscous media
Process connection G 1½-ISO 228 male, incl. O-rings
Measuring range (temperature) 0...90 °C
Accuracy (temperature) ±1 k
Pressure rating PN 16

Temperature ranges

Medium
Ambient

 

-20...90 °C
-20...70 °C

Frequency output Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 20 mA

Analogue output

Output signal flow
 


0.5...3.5 V
0...10 V or 4...20 mA

Power supply 8...30 V DC or 5 V DC (±5 %) or 12...24 VDC***
Electrical connection 5-pin plug connector M12 x 1
Degree of protection EN 60529 IP65**

* Test conditions: See data sheet
** With attached cable socket only
*** Only available for output signal flow 4...20 mA and 0...10 V

** NEW ** Vortex flow sensor Type VVX40

SIKA VVX40 flow sensors are used for measuring water flow at medium and high measurement ranges.
One such application area is large heat pumps.

Nominal diameter DN 40
Measuring range (flow) 22...400 l/min
Accuracy (flow) ±2 % of range*, deviations with high viscous media
Process connection G 2-ISO 228 male, incl. O-rings
Measuring range (temperature) 0...90 °C
Accuracy (temperature) ±1 k
Pressure rating PN 16

Temperature ranges

Medium
Ambient

 

-20...90 °C
-20...70 °C

Frequency output Frequency signal, square wave, pulse duty ratio 50:50, signal current max. 20 mA

Analogue output

Output signal flow
 


0.5...3.5 V
0...10 V or 4...20 mA

Power supply 8...30 V DC or 5 V DC (±5 %) or 12...24 VDC***
Electrical connection 5-pin plug connector M12 x 1
Degree of protection EN 60529 IP65**

* Test conditions: See data sheet
*** With attached cable socket only
**** Only available for output signal flow 4...20 mA and 0...10 V

© 2015 HAK - All Rights Reserved – By eureka digital.